Dear All,
I have found errors in my calculation. In estimating BN/B1,
factorial N! was missing. So for the case of sextupole field
(N=2), the tolerance was larger by factor 2.
I also changed the radius r to be 10mm instead of 16mm, and
E=1.3 GeV.
Please find the new results in the attached file( Excel ).
SX component should be less than 0.04% for 20cm Q and 3e-5
for FD which would be a problem.
For higher order component( N=5 and 9 ), the tolerance becomes
tighter but still realistic, I think.
N=5 <10% for 20cm Q
<0.2% for FD
N=9 <100% for 20cm Q
<4% for FD
Please check and comment.
Best Regards,